Cut-to-Length (Per Foot) Mid-Temperature Self-Regulating Heating Cable 110-120v 10W/ft Tinned Copper Metal Braid <br><font color="#008000" >Free Shipping</font>
Zoom

Cut-to-Length (Per Foot) Mid-Temperature Self-Regulating Heating Cable 110-120v 10W/ft Tinned Copper Metal Braid
Free Shipping

Item Number# 8BHSLMCAB10120B
Buy More, Save More!
QuantityPrice Each
1 - 99 pieces$13.98 ea.
100 - 999 pieces$12.98 ea.
1000 - 4999 pieces$11.98 ea.
5000+ pieces$10.98 ea.

  • Description
  • Specs
  • You May Also Need
  • Q&As
  • PDFs
  • Reviews

Description

110-120v | 10W/ft (31W/m) | Tinned Copper Overjacket, Metal Braid Cut-to-Length, Mid-Temperature Self-Regulating Heating Cable (SLMCAB)

  1. Ideal for freeze protection and mid-temperature process maintenance up to 250°F (120°C)
  2. Automatically adjusts heat output based upon surface temperature and ambient conditions
  3. Safe to overlap and insulate Moisture, chemical, and flame resistant
  4. Can be cut-to-length and terminated in the field

Specifications

  • Continuous Maintenance Temperature: Max 250°F (120°C)
  • Intermittent Exposure Temperature: -40°F to 366°F (-40°C to 185°C )
  • Output Wattages: 5, 10, 15 W/ft (16, 33, 49 W/m)
  • Supply Voltages: 110 to 120 VAC or 208 to 277 VAC

Q & A's

Questions & Answers about Cut-to-Length (Per Foot) Mid-Temperature Self-Regulating Heating Cable 110-120v 10W/ft Tinned Copper Metal Braid
Free Shipping

Question: "What is self-regulating cable?"
Answer: "Self-regulating cable, also known as heat tape or heat trace, is a semi-flexible heating cable that automatically regulates its heat output based upon surface temperature and ambient conditions. It is often used for freeze protection applications to wrap or trace pipes, tanks, vessels, roofing, and much more."
Question: "What is a Class I/Division 1 environment?"
Answer: "Class I/Division 1 is an environment in which ignitable concentrations of flammable gases or vapors may exist under normal operating conditions, uring repair and maintenance, or where faulty equipment might release these flammable gasses or vapors."
Question: "Where do I find Class I /Division 1 environments?"
Answer: "Common industries include Oil, Hydrocarbon & Gas Exploration and Refining, Chemical Manufacturing/Processing, Paint Production, Mining, Coal Processing, and many more."
Question: "How much heat does selfregulating cable generate?"
Answer:Depending upon model and wattage, heat output can vary greatly. Maximum operating temperatures range from 150°F to 392°F (65°C to 120°C), but because of the selfregulating design, actual temperatures are normally much lower.
Question: "What is the maximum allowable circuit length?"
Answer: "Depending on wattage, voltage, and circuit capacity, circuit lengths can range from 32 ft to 660 ft."
Question: "How do I select the best heating cable for my application?"
Answer: "BriskHeat provides, at no charge, a full-service heat-loss calculation and engineering support to make a recommendation based on the specifications of your application."
Question: "Do I need to insulate over the cable?"
Answer: "Yes, insulation is always recommended to maximize thermal performance and efficiency."
Question: "What insulation should I use with Self-Regulating heating cable?"
Answer:"Depending on the application, BriskHeat offers two types of insulation; Insul-Lock pre-formed foam insulation for pipe, and Silver-Series cloth insulators for pipe, valves, flanges, etc., as well as custom designed insulators. Contact BriskHeat to determine which best fits your requirements."

Ask a question about Cut-to-Length (Per Foot) Mid-Temperature Self-Regulating Heating Cable 110-120v 10W/ft Tinned Copper Metal Braid
Free Shipping
. Click here
Scroll to top